Current transformer CG Split core, 400A/5A Ø36mm
Carlo Gavazzi split-core current transformer for AC current measurement up to 400 A.
The 400A/5A transformer provides a standard 5 A secondary output and a Ø36 mm conductor opening, making it suitable for larger cables and retrofit energy monitoring.
- 400 A primary current
- 5 A secondary output
- Ø36 mm opening
- Split-core construction
- Suitable for retrofit installations
Split-core current transformer for AC current measurement
The Current transformer CG Split core, 400A/5A Ø36mm is a Carlo Gavazzi split-core current transformer designed for AC current measurement in existing electrical installations. The split-core construction allows installation around an existing conductor without removing the cable, making it suitable for retrofit energy monitoring and sub-metering.
The transformer has a rated primary current of 400 A and provides a standard 5 A secondary output for connection to compatible energy meters, power analyzers and monitoring equipment.
400 A current measurement with 36 mm opening
The Ø36 mm conductor opening provides space for larger cables in distribution boards, switchboards and industrial installations. The opening core simplifies mechanical installation compared with conventional solid-core current transformers.
The current transformer is suitable for load monitoring, sub-metering and energy management applications where the connected measuring equipment uses a 5 A current-transformer input.
See the official Carlo Gavazzi current transformer documentation for detailed technical specifications and installation requirements.
Product benefits
- Split-core construction for retrofit installation
- Rated primary current of 400 A
- Standard 5 A secondary output
- Ø36 mm conductor opening
- Suitable for larger cables
- Designed for current and energy monitoring
- Compatible with measuring equipment using 5 A CT inputs
Technical specifications
| Product | Current transformer CG Split core, 400A/5A Ø36mm |
|---|---|
| Manufacturer | Carlo Gavazzi |
| Transformer type | Split-core current transformer |
| Rated primary current | 400 A |
| Secondary output | 5 A |
| Transformation ratio | 400/5 A |
| Conductor opening | Ø36 mm |
| Application | AC current and energy measurement |
Applications
- Energy monitoring systems
- Electrical distribution boards
- Building energy management
- Industrial load monitoring
- Retrofit current measurement
Installation and connection
Open the split-core transformer and install it around the relevant phase conductor while observing the correct current direction and polarity. Connect the 5 A secondary circuit to compatible measuring equipment. Current-transformer secondary circuits must be installed according to applicable electrical safety requirements and should be handled by qualified personnel.